A05VVF 3G 6 #C #T

Description

Description

Standards

  • Product
    NF C32-206
  • Test
    IEC 60332-1-2
  • National
    ELOT 563.1

Application and design

Cable with flexible copper conductors suitable for installation in dry or wet places

  1. Flexible copper conductor
  2. PVC insulation
  3. PVC outer sheath

 

Insulation colors

2-cores: brown, blue

3-cores: brown, yellow-green, blue

4-cores: brown, black, grey, yellow-green

5-cores: brown, black, grey, yellow-green, blue

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Flexible class 5
Conductor shape
Circular
Insulation
PVC
Outer sheath
PVC
Sheath colour
White
With Green/Yellow core
Yes
Lead free
Yes
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
6 mm²
Phase Conductor Cross Section
6 mm²
Ground conductor cross-section
6 mm²
Nominal insulation thickness
0.8 mm
Nominal outer sheath thickness
1.4 mm
Nominal outer diameter
14.0 mm
Approximate weight
310 kg/km
Neutral conductor section (when smaller)
- mm²

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
300/500 V
Max. DC resistance of the conductor at 20°C
3.3 Ohm/km
Maximum permissible nominal current
47 A

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible

Resources

Resources

Current capacity table PVC insulation multicore single phase

PVC insulation/two loaded conductors, copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in ground
Conductor cross-section A2 Multi-core cable in conduit in a thermally insulated wall B2 Multi-core cable in conduit on a wooden wall C Single-core or multi-core cable on a wooden wall D1 Single-core or Multi-core cable in ducts in the ground D2 Single-core or Multi-core cables designed to be buried directly in the ground E Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
6.0 32.0 25.0 38.0 30.0 46.0 36.0 46.0 36.0 48.0 0.0 51.0 39.0

Current capacity table PVC insulation multicore three phase

PVC insulation, three loaded conductors/copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in ground
Conductor cross-section A2 Multi-core cable in conduit in a thermally insulated wall B2 Multi-core cable in conduit on a wooden wall C Single-core or multi-core cable on a wooden wall D1 Single-core or Multi-core cable in ducts in the ground D2 Single-core or Multi-core cables designed to be buried directly in the ground E Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
6.0 29.0 23.0 34.0 27.0 41.0 32.0 38.0 30.0 41.0 0.0 43.0 33.0

Declaration of Performance

  • Declaration of Performance n� : 1000791-GRLA
  • Certification Date : 12/19/18
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0051
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close