- Company
- Markets
-
Products
- Products
- Building cables
- Outdoor/Industrial Non Armored Cables
- Outdoor/Industrial Armored Cables
- Earth Conductors
- Solar farms
- Safety Cables
- Power Distribution Aerial cables
- Power Transmission & Distribution Conductors OHL
- Power Distribution cables
-
MV Underground Armored cables
- Overview
- CU/XLPE/CTS/LSF/AWA/LSF 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV
- CU/XLPE/CTS/LSF/SWA/LSF 6.35/11 KV
- CU/XLPE/CTS/PVC/SWA/PVC 19/33KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33KV
- CU/XLPE/CTS/PVC/AWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33 KV RED STRIPE
-
MV Underground Unarmored cables
- Overview
- NA2XS(F)2Y RM 6/10 KV
- CU/XLPE/CWS/PE 6.35/11KV - BS 7870-4.10
- A2XS(F)2Y 12/20KV - IEC
- NA2XS(F)2Y RM 18/30 kV
- AL/XLPE/CWS/PVC 12/20KV - DEH
- NA2XS(F)2Y RM 12/20 kV
- CU/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- 2XSY 12/20 KV - IEC
- AL/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- AL/XLPE/PVC 12/20KV - triplex - Underground - DEH
- A2XSY 12/20KV - IEC
- CU/XLPE/CWS/PVC 12/20KV 3-CORE -IEC
- AL/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/CWS/WB/PE 19/33KV - BS 7870-4.10
- AL/XLPE/CWS/PE 19/33KV - BS 7870-4.10
- AL/XLPE/AWS/WB/PE 19/33KV
- AL/XLPE/CWS/PE/SC 19/33KV - BS 7870-4.10
- A2XSH 12/20KV - DEH
- AXCLIGHT TT 12kV
- AXCLIGHT TT E 36kV
- NA2XS(FL)2Y V RM 12/20 kV
- AXCLIGHT TT 24kV
- CU/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/AL-PE/PE 12/20KV 3.0 - IEC
- NA2XS(F)2Y RM 12/20 kV - triplex
- AL/XLPE/CWS/PE 6.35/11KV - BS 7870-4.20
- NA2XS(F)2Y V RM 12/20 kV
- AXLJ TT 36 kV
- CU/XLPE/AWS/LSF 6.35/11KV - IEC
- NA2XS2Y RM 6/10 KV - Triplex
- Newsroom
- Tools & Resources
- Newsletter
- Search
- Contact us
- Compare
- Sign in
U-1000 R2V single core
U-1000 R2V single core
Electric cable for fixed installation. Rated voltage 600/1000V
Read moreR2V 1X 16 R #D
Nexans ref. 13003222 - Country ref. 13003222
- Packaging: Cut to length (m)
- Conductor cross-section: 16 mm²
- Phase Conductor Cross Section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 9.2 mm
- Approximate weight: 190 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating when buried: 107 A
- Permissible current rating in open air: 113 A
- Voltage drop, 3 conductors: 2.1 V/A.km
R2V 1X 25 C #D
Nexans ref. 13000311 - Country ref. 13000311
- Packaging: Cut to length (m)
- Conductor cross-section: 25 mm²
- Phase Conductor Cross Section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 10.5 mm
- Approximate weight: 270 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating when buried: 138 A
- Permissible current rating in open air: 144 A
- Voltage drop, 3 conductors: 1.4 V/A.km
R2V 1X 35 C #D
Nexans ref. 13000312 - Country ref. 13000312
- Packaging: Cut to length (m)
- Conductor cross-section: 35 mm²
- Phase Conductor Cross Section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 11.5 mm
- Approximate weight: 370 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating when buried: 169 A
- Permissible current rating in open air: 174 A
- Voltage drop, 3 conductors: 1.0 V/A.km
R2V 1X 50 C #D
Nexans ref. 13000313 - Country ref. 13000313
- Packaging: Cut to length (m)
- Conductor cross-section: 50 mm²
- Phase Conductor Cross Section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 12.5 mm
- Approximate weight: 490 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating when buried: 206 A
- Permissible current rating in open air: 207 A
- Voltage drop, 3 conductors: 0.78 V/A.km
R2V 1X 70 C #D
Nexans ref. 13000314 - Country ref. 13000314
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Phase Conductor Cross Section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 14.5 mm
- Approximate weight: 685 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating when buried: 254 A
- Permissible current rating in open air: 268 A
- Voltage drop, 3 conductors: 0.56 V/A.km
R2V 1X 95 C #D
Nexans ref. 13000315 - Country ref. 13000315
- Packaging: Cut to length (m)
- Conductor cross-section: 95 mm²
- Phase Conductor Cross Section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 1.5 mm
- Nominal outer diameter: 16.5 mm
- Approximate weight: 930 kg/km
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating when buried: 301 A
- Permissible current rating in open air: 328 A
- Voltage drop, 3 conductors: 0.43 V/A.km
R2V 1X120 C #D
Nexans ref. 13000316 - Country ref. 13000316
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Phase Conductor Cross Section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal outer sheath thickness: 1.5 mm
- Nominal outer diameter: 18.0 mm
- Approximate weight: 1170 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating when buried: 343 A
- Permissible current rating in open air: 382 A
- Voltage drop, 3 conductors: 0.36 V/A.km
R2V 1X150 C #D
Nexans ref. 13000317 - Country ref. 13000317
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Phase Conductor Cross Section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Nominal outer sheath thickness: 1.6 mm
- Nominal outer diameter: 20.0 mm
- Approximate weight: 1430 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating when buried: 387 A
- Permissible current rating in open air: 441 A
- Voltage drop, 3 conductors: 0.31 V/A.km
R2V 1X185 C #D
Nexans ref. 13000319 - Country ref. 13000319
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Phase Conductor Cross Section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Nominal outer sheath thickness: 1.6 mm
- Nominal outer diameter: 22.0 mm
- Approximate weight: 1785 kg/km
- Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
- Permissible current rating when buried: 434 A
- Permissible current rating in open air: 506 A
- Voltage drop, 3 conductors: 0.26 V/A.km
R2V 1X240 C #D
Nexans ref. 13000320 - Country ref. 13000320
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Phase Conductor Cross Section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Nominal outer sheath thickness: 1.7 mm
- Nominal outer diameter: 24.6 mm
- Approximate weight: 2290 kg/km
- Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
- Permissible current rating when buried: 501 A
- Permissible current rating in open air: 599 A
- Voltage drop, 3 conductors: 0.22 V/A.km
R2V 1X300 C #D
Nexans ref. 13001050 - Country ref. 13001050
- Packaging: Cut to length (m)
- Conductor cross-section: 300 mm²
- Phase Conductor Cross Section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 27.5 mm
- Approximate weight: 2900 kg/km
- Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
- Permissible current rating when buried: 565 A
- Permissible current rating in open air: 693 A
- Voltage drop, 3 conductors: 0.19 V/A.km
R2V 1X400 C #D
Nexans ref. 13000321 - Country ref. 13000321
- Packaging: Cut to length (m)
- Conductor cross-section: 400 mm²
- Phase Conductor Cross Section: 400 mm²
- Nominal insulation thickness: 2.0 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 30.4 mm
- Approximate weight: 3715 kg/km
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating when buried: 662 A
- Permissible current rating in open air: 825 A
- Voltage drop, 3 conductors: 0.17 V/A.km
R2V 1X500 C #D
Nexans ref. 13005119 - Country ref. 13005119
- Packaging: Cut to length (m)
- Conductor cross-section: 500 mm²
- Phase Conductor Cross Section: 500 mm²
- Nominal insulation thickness: 2.2 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 34.0 mm
- Approximate weight: 4840 kg/km
- Max. DC resistance of the conductor at 20°C: 0.037 Ohm/km
- Permissible current rating when buried: 750 A
- Permissible current rating in open air: 946 A
- Voltage drop, 3 conductors: 0.15 V/A.km
Description
Description
Standards
-
ProductIEC 60502-1; XP C 32-321
-
TestIEC 60332-1
Application
Electric cable with copper solid or stranded conductors with PVC insulation and PVC outer sheath.
The cable is suitable for fixed installations, indoor and outdoor.
According to CPR regulation the cable is Euroclass Eca
Construction
1. copper conductor
2. XLPE insulation
3. PVC outer sheath
Note: U:circular solid conductor, R:circular stranded conductor, S:sector-shaped stranded conductor
Note: upon request the cable could be available with higher fire retardant performance to meet the standard IEC 60322-3-24 cat C
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Current capacity table XLPE insulation single core three phase
XLPE or EPR insulation, three loaded conductors/copper or aluminium –
Conductor temperature: 90 °C, ambient temperature: 30 °C in air, 20 °C in ground
Conductor cross-section | A1 Insulated conductors in conduit in a thermally insulated wall | B1 Insulated conductors in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | F Single-core flat cables, touching in free air | F Single-core trefoil cables, touching in free air | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
1.5 | 17.0 | 0.0 | 20.0 | 0.0 | 22.0 | 0.0 | 21.0 | 0.0 | 23.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2.5 | 23.0 | 19.0 | 28.0 | 22.0 | 30.0 | 24.0 | 28.0 | 22.0 | 30.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
4.0 | 31.0 | 25.0 | 37.0 | 29.0 | 40.0 | 32.0 | 36.0 | 28.0 | 39.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
6.0 | 40.0 | 32.0 | 48.0 | 38.0 | 52.0 | 41.0 | 44.0 | 35.0 | 49.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
10.0 | 54.0 | 44.0 | 66.0 | 52.0 | 71.0 | 57.0 | 58.0 | 46.0 | 65.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
16.0 | 73.0 | 58.0 | 88.0 | 71.0 | 96.0 | 76.0 | 75.0 | 59.0 | 84.0 | 64.0 | 0.0 | 0.0 | 0.0 | 0.0 |
25.0 | 95.0 | 76.0 | 117.0 | 93.0 | 119.0 | 90.0 | 96.0 | 75.0 | 107.0 | 82.0 | 141.0 | 107.0 | 135.0 | 103.0 |
35.0 | 117.0 | 94.0 | 144.0 | 116.0 | 147.0 | 112.0 | 115.0 | 90.0 | 129.0 | 98.0 | 176.0 | 135.0 | 169.0 | 129.0 |
50.0 | 141.0 | 113.0 | 175.0 | 140.0 | 179.0 | 136.0 | 135.0 | 106.0 | 153.0 | 117.0 | 216.0 | 165.0 | 207.0 | 159.0 |
70.0 | 179.0 | 142.0 | 222.0 | 179.0 | 229.0 | 174.0 | 167.0 | 130.0 | 188.0 | 144.0 | 279.0 | 215.0 | 268.0 | 206.0 |
95.0 | 216.0 | 171.0 | 269.0 | 217.0 | 278.0 | 211.0 | 197.0 | 154.0 | 226.0 | 172.0 | 342.0 | 264.0 | 328.0 | 253.0 |
120.0 | 249.0 | 197.0 | 312.0 | 251.0 | 322.0 | 245.0 | 223.0 | 174.0 | 257.0 | 197.0 | 400.0 | 308.0 | 383.0 | 296.0 |
150.0 | 285.0 | 226.0 | 342.0 | 267.0 | 371.0 | 283.0 | 251.0 | 197.0 | 287.0 | 220.0 | 464.0 | 358.0 | 444.0 | 343.0 |
185.0 | 324.0 | 256.0 | 384.0 | 300.0 | 424.0 | 323.0 | 281.0 | 220.0 | 324.0 | 250.0 | 533.0 | 413.0 | 510.0 | 395.0 |
240.0 | 380.0 | 300.0 | 450.0 | 351.0 | 500.0 | 382.0 | 324.0 | 253.0 | 375.0 | 290.0 | 634.0 | 492.0 | 607.0 | 471.0 |
300.0 | 435.0 | 344.0 | 514.0 | 402.0 | 576.0 | 440.0 | 365.0 | 286.0 | 419.0 | 326.0 | 736.0 | 571.0 | 703.0 | 547.0 |
400.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 868.0 | 694.0 | 823.0 | 663.0 |
500.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 998.0 | 806.0 | 946.0 | 770.0 |
630.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 1151.0 | 942.0 | 1088.0 | 899.0 |
Current capacity table XLPE insulation single core single phase
XLPE or EPR insulation, two loaded conductors/copper or aluminium
Conductor temperature: 90 °C, ambient temperature: 30 °C in air, 20 °C in ground
Conductor cross-section | A1 Insulated conductors in conduit in a thermally insulated wall | B1 Insulated conductors in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | F Single-core flat cables, touching in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
1.5 | 19.0 | 0.0 | 23.0 | 0.0 | 24.0 | 0.0 | 26.0 | 0.0 | 27.0 | 0.0 | 0.0 | 0.0 |
2.5 | 26.0 | 20.0 | 31.0 | 25.0 | 33.0 | 26.0 | 33.0 | 26.0 | 35.0 | 0.0 | 0.0 | 0.0 |
4.0 | 35.0 | 27.0 | 42.0 | 33.0 | 45.0 | 35.0 | 43.0 | 33.0 | 46.0 | 0.0 | 0.0 | 0.0 |
6.0 | 45.0 | 35.0 | 54.0 | 43.0 | 58.0 | 45.0 | 53.0 | 42.0 | 58.0 | 0.0 | 0.0 | 0.0 |
10.0 | 61.0 | 48.0 | 75.0 | 59.0 | 80.0 | 62.0 | 71.0 | 55.0 | 77.0 | 0.0 | 0.0 | 0.0 |
16.0 | 81.0 | 64.0 | 100.0 | 79.0 | 107.0 | 84.0 | 91.0 | 71.0 | 100.0 | 76.0 | 0.0 | 0.0 |
25.0 | 106.0 | 84.0 | 133.0 | 105.0 | 138.0 | 101.0 | 116.0 | 90.0 | 129.0 | 98.0 | 161.0 | 121.0 |
35.0 | 131.0 | 103.0 | 164.0 | 130.0 | 171.0 | 126.0 | 139.0 | 108.0 | 155.0 | 117.0 | 200.0 | 150.0 |
50.0 | 158.0 | 125.0 | 198.0 | 157.0 | 209.0 | 154.0 | 164.0 | 128.0 | 183.0 | 139.0 | 242.0 | 184.0 |
70.0 | 200.0 | 158.0 | 253.0 | 200.0 | 269.0 | 198.0 | 203.0 | 158.0 | 225.0 | 170.0 | 310.0 | 237.0 |
95.0 | 241.0 | 191.0 | 306.0 | 242.0 | 328.0 | 241.0 | 239.0 | 186.0 | 270.0 | 204.0 | 377.0 | 289.0 |
120.0 | 278.0 | 220.0 | 354.0 | 281.0 | 382.0 | 280.0 | 271.0 | 211.0 | 306.0 | 233.0 | 437.0 | 337.0 |
150.0 | 318.0 | 253.0 | 393.0 | 307.0 | 441.0 | 324.0 | 306.0 | 238.0 | 343.0 | 261.0 | 504.0 | 389.0 |
185.0 | 362.0 | 288.0 | 449.0 | 351.0 | 506.0 | 371.0 | 343.0 | 267.0 | 387.0 | 296.0 | 575.0 | 447.0 |
240.0 | 424.0 | 338.0 | 528.0 | 412.0 | 599.0 | 439.0 | 395.0 | 307.0 | 448.0 | 343.0 | 679.0 | 530.0 |
300.0 | 486.0 | 387.0 | 603.0 | 471.0 | 693.0 | 508.0 | 446.0 | 346.0 | 502.0 | 386.0 | 783.0 | 613.0 |
400.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 940.0 | 740.0 |
500.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 1083.0 | 856.0 |
630.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 1254.0 | 996.0 |
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania