- Company
- Markets
-
Products
- Products
- Building cables
- Outdoor/Industrial Non Armored Cables
- Outdoor/Industrial Armored Cables
- Earth Conductors
- Solar farms
- Safety Cables
- Power Distribution Aerial cables
- Power Transmission & Distribution Conductors OHL
- Power Distribution cables
-
MV Underground Armored cables
- Overview
- CU/XLPE/CTS/LSF/AWA/LSF 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV
- CU/XLPE/CTS/LSF/SWA/LSF 6.35/11 KV
- CU/XLPE/CTS/PVC/SWA/PVC 19/33KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33KV
- CU/XLPE/CTS/PVC/AWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33 KV RED STRIPE
-
MV Underground Unarmored cables
- Overview
- NA2XS(F)2Y RM 6/10 KV
- CU/XLPE/CWS/PE 6.35/11KV - BS 7870-4.10
- A2XS(F)2Y 12/20KV - IEC
- NA2XS(F)2Y RM 18/30 kV
- AL/XLPE/CWS/PVC 12/20KV - DEH
- NA2XS(F)2Y RM 12/20 kV
- CU/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- 2XSY 12/20 KV - IEC
- AL/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- AL/XLPE/PVC 12/20KV - triplex - Underground - DEH
- A2XSY 12/20KV - IEC
- CU/XLPE/CWS/PVC 12/20KV 3-CORE -IEC
- AL/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/CWS/WB/PE 19/33KV - BS 7870-4.10
- AL/XLPE/CWS/PE 19/33KV - BS 7870-4.10
- AL/XLPE/AWS/WB/PE 19/33KV
- AL/XLPE/CWS/PE/SC 19/33KV - BS 7870-4.10
- A2XSH 12/20KV - DEH
- AXCLIGHT TT 12kV
- AXCLIGHT TT E 36kV
- NA2XS(FL)2Y V RM 12/20 kV
- AXCLIGHT TT 24kV
- CU/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/AL-PE/PE 12/20KV 3.0 - IEC
- NA2XS(F)2Y RM 12/20 kV - triplex
- AL/XLPE/CWS/PE 6.35/11KV - BS 7870-4.20
- NA2XS(F)2Y V RM 12/20 kV
- AXLJ TT 36 kV
- CU/XLPE/AWS/LSF 6.35/11KV - IEC
- NA2XS2Y RM 6/10 KV - Triplex
- Newsroom
- Tools & Resources
- Newsletter
- Search
- Contact us
- Compare
- Sign in
A05VVU 3G 1.5 #C
A05VVU 3G 1.5 #C
A05VVU 3G 1.5 #C
Read more- Nexans ref. : 13001164
- Country ref. : 13001164
- EAN : 5204609011640
Description
Description
Standards
-
TestIEC 60332-1
-
InternationalHD 21.4
-
NationalELOT 563.4
Copper cable with solid or stranded copper conductor suitable for installation in dry or wet places.
Design
- Copper conductor
- PVC Insulation
- PVC Outer sheath
Core marking
2-cores: Brown, Blue
3-cores: Brown, Yellow-green, Blue
4-cores: Brwon, Black, Grey, Yellow-green
5-cores: Brown, Black, Grey, Yellow-green, Blue
Cable construction
1. copper conductor
2. PVC insulation
3. PVC outer sheath
Note: upon request the cable could be manufactured with higher fire retardant performance to meet the standards BS/EN 50266 cat C, IEC 60332-3-24 cat C
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Copper
Conductor shape
Round, massive
Conductor flexibility
Solid class 1
Insulation
PVC
Outer sheath
PVC
Sheath colour
White
Type of conductor
U
With Green/Yellow core
Yes
With smaller neutral conductor
No
Dimensional characteristics
Dimensional characteristics
Number of cores
3
Approximate weight
135 kg/km
Conductor cross-section
1.5 mm²
Phase Conductor Cross Section
1.5 mm²
Ground conductor cross-section
1.5 mm²
Wire section
- mm²
Nominal insulation thickness
0.7 mm
Nominal outer sheath thickness
1.2 mm
Nominal outer diameter
9.0 mm
Neutral conductor section (when smaller)
- mm²
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
300/500 V
Max. DC resistance of the conductor at 20°C
12.1 Ohm/km
Maximum permissible nominal current
20 A
Voltage drop, single phase
29.0 V/A.km
Voltage drop, 3 conductors
25.0 V/A.km
Resources
Resources
Current capacity table PVC insulation single core three phase
PVC insulation/three loaded conductors, copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in groundConductor cross-section | A1 Insulated conductors in conduit in a thermally insulated wall | B1 Insulated conductors in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | F Single-core flat cables, touching in free air | F Single-core trefoil cables, touching in free air | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
1.5 | 13.5 | 0.0 | 15.5 | 0.0 | 17.5 | 0.0 | 18.0 | 0.0 | 19.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
Current capacity table PVC insulation multicore three phase
PVC insulation, three loaded conductors/copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in groundConductor cross-section | A2 Multi-core cable in conduit in a thermally insulated wall | B2 Multi-core cable in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | E Multi-core cable in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
1.5 | 13.0 | 0.0 | 15.0 | 0.0 | 17.5 | 0.0 | 18.0 | 0.0 | 19.0 | 0.0 | 18.5 | 0.0 |
Current capacity table PVC insulation multicore single phase
PVC insulation/two loaded conductors, copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in groundConductor cross-section | A2 Multi-core cable in conduit in a thermally insulated wall | B2 Multi-core cable in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | E Multi-core cable in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
1.5 | 14.0 | 0.0 | 16.5 | 0.0 | 19.5 | 0.0 | 22.0 | 0.0 | 22.0 | 0.0 | 22.0 | 0.0 |
Current capacity table PVC insulation single core single phase
PVC insulation/two loaded conductors, copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in groundConductor cross-section | A1 Insulated conductors in conduit in a thermally insulated wall | B1 Insulated conductors in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | F Single-core flat cables, touching in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
1.5 | 14.5 | 0.0 | 17.5 | 0.0 | 19.5 | 0.0 | 22.0 | 0.0 | 22.0 | 0.0 | 0.0 | 0.0 |
Declaration of Performance
- Declaration of Performance n� : 1000423-GRLA
- Certification Date : 7/3/17
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : 0832
- Declared performance : Eca
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania