H07VU 1X 4 BR #C 150M

Description

Description

Standards

  • Product
    BS 6004; EN 50525-2-31; HD 21.3; IEC 60227-1
  • National
    ELOT 563.3

Single core non-sheathed power cable with copper conductor and PVC insulation suitable for rated voltages 450/750V

 

Application

H07V-U and H07V-R are used for fixed protected installations in, or on, lighting or controlgear...

 

Installation

In cable dusts, in trunks or in cable conduits

 

Colours

Black, Brown, Blue, Yellow-green

Note: on request the cables are available in other colours such as: Red, Grey, Orange, White,...

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Type of conductor
U
Conductor flexibility
Solid class 1
Conductor shape
Circular
Insulation
PVC
Colour
Brown
Lead free
Yes
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Number of cores
1
Conductor cross-section
4 mm²
Phase Conductor Cross Section
4 mm²
Nominal insulation thickness
0.8 mm
Nominal outer diameter
4.4 mm
Approximate weight
43 kg/km
Neutral conductor section (when smaller)
- mm²

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
450/750 V
Max. DC resistance of the conductor at 20°C
4.61 Ohm/km
Maximum permissible nominal current
27 A
Voltage drop, single phase
11.0 V/A.km
Voltage drop, 3 conductors
9.5 V/A.km

Usage characteristics

Usage characteristics

Operating temperature, range
-5 ... 60 °C
Max. conductor temperature in service
70 °C
Short-circuit max. conductor temperature
160 °C

Resources

Resources

Current capacity table PVC insulation single core single phase

PVC insulation/two loaded conductors, copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in ground
Conductor cross-section A1 Insulated conductors in conduit in a thermally insulated wall B1 Insulated conductors in conduit on a wooden wall C Single-core or multi-core cable on a wooden wall D1 Single-core or Multi-core cable in ducts in the ground D2 Single-core or Multi-core cables designed to be buried directly in the ground F Single-core flat cables, touching in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
4.0 26.0 20.0 32.0 25.0 36.0 28.0 37.0 29.0 38.0 0.0 0.0 0.0

Current capacity table PVC insulation single core three phase

PVC insulation/three loaded conductors, copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in ground
Conductor cross-section A1 Insulated conductors in conduit in a thermally insulated wall B1 Insulated conductors in conduit on a wooden wall C Single-core or multi-core cable on a wooden wall D1 Single-core or Multi-core cable in ducts in the ground D2 Single-core or Multi-core cables designed to be buried directly in the ground F Single-core flat cables, touching in free air F Single-core trefoil cables, touching in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
4.0 24.0 18.5 28.0 22.0 32.0 25.0 30.0 24.0 33.0 0.0 0.0 0.0 0.0 0.0

Selling & delivery Information

Type conductor: U (solid, class 1) or R (circular stranded, class 2)

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close