H07VR 1X 4 BR #C
H07VR 1X 4 BR #C
H07VR 1X 4 BR #C
Read more- Nexans ref. : 13004767
- Country ref. : 13004767
- EAN : 5204609053909
Description
Description
Standards
-
ProductBS 6004; EN 50525-2-31; HD 21.3; IEC 60227-1
-
NationalELOT 563.3
Application and design
Single core non-sheathed power cable with copper conductor, PVC insulation
Installation: indoor, fixed protected installations, in dusts or trays
Type conductor: U (solid, class 1), R (circular stranded, class 2)
Installation colors
Brown, Black, Grey, Blue, Yellow-green
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Copper
Type of conductor
R
Conductor flexibility
Stranded class 2
Conductor shape
Circular
Insulation
PVC
Colour
Brown
Lead free
Yes
With Green/Yellow core
No
With smaller neutral conductor
No
Dimensional characteristics
Dimensional characteristics
Number of cores
1
Conductor cross-section
4 mm²
Phase Conductor Cross Section
4 mm²
Nominal insulation thickness
0.8 mm
Nominal outer diameter
4.6 mm
Approximate weight
47 kg/km
Neutral conductor section (when smaller)
- mm²
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
450/750 V
Max. DC resistance of the conductor at 20°C
4.61 Ohm/km
Maximum permissible nominal current
27 A
Voltage drop, single phase
11.0 V/A.km
Voltage drop, 3 conductors
9.5 V/A.km
Usage characteristics
Usage characteristics
Operating temperature, range
-5 ... 60 °C
Max. conductor temperature in service
70 °C
Short-circuit max. conductor temperature
160 °C
Resources
Resources
Current capacity table PVC insulation single core single phase
PVC insulation/two loaded conductors, copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in groundConductor cross-section | A1 Insulated conductors in conduit in a thermally insulated wall | B1 Insulated conductors in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | F Single-core flat cables, touching in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Conductor cross-section 4.0 |
A1 Insulated conductors in conduit in a thermally insulated wall
26.0 |
B1 Insulated conductors in conduit on a wooden wall
20.0 |
C Single-core or multi-core cable on a wooden wall
32.0 |
D1 Single-core or Multi-core cable in ducts in the ground
25.0 |
D2 Single-core or Multi-core cables designed to be buried directly in the ground
36.0 |
F Single-core flat cables, touching in free air
28.0 |
mm² 37.0 |
Cu 29.0 |
Al 38.0 |
Cu 0.0 |
Al 0.0 |
Cu 0.0 |
Current capacity table PVC insulation single core three phase
PVC insulation/three loaded conductors, copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in groundConductor cross-section | A1 Insulated conductors in conduit in a thermally insulated wall | B1 Insulated conductors in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | F Single-core flat cables, touching in free air | F Single-core trefoil cables, touching in free air | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Conductor cross-section 4.0 |
A1 Insulated conductors in conduit in a thermally insulated wall
24.0 |
B1 Insulated conductors in conduit on a wooden wall
18.5 |
C Single-core or multi-core cable on a wooden wall
28.0 |
D1 Single-core or Multi-core cable in ducts in the ground
22.0 |
D2 Single-core or Multi-core cables designed to be buried directly in the ground
32.0 |
F Single-core flat cables, touching in free air
25.0 |
F Single-core trefoil cables, touching in free air
30.0 |
mm² 24.0 |
Cu 33.0 |
Al 0.0 |
Cu 0.0 |
Al 0.0 |
Cu 0.0 |
Al 0.0 |
Selling & delivery Information
Type conductor: U (solid, class 1) or R (circular stranded, class 2)
Declaration of Performance
- Declaration of Performance n� : 1000425-GRLA
- Certification Date : 7/3/17
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : 0832
- Declared performance : Eca
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania