ruNeasy H07V-U 2.5 mm2 BL #C
ruNeasy H07V-U 2.5 mm2 BL #C
ruNeasy H07V-U 2.5 mm2 BL #C
Read more- Nexans ref. : 13006395
- Country ref. : 13006395
- EAN : 5204609072696
Description
Description
Standards
-
ProductBS 6004; EN 50525-2-31; HD 21.3; IEC 60227-1
-
NationalELOT 563.3
Application and design
Single core non-sheathed power cable with copper conductor, PVC insulation
Type conductor: U (solid, class 1) or R (circular stranded, class 2)
Installation: indoor, fixed protected installations, in dusts. Suitable for fast installation inside pipes
Insulation colors
Brown, Black, Grey, Blue, Yellow-green
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Copper
Type of conductor
U
Conductor flexibility
Solid class 1
Conductor shape
Circular
Insulation
PVC
Colour
Blue
Lead free
Yes
With Green/Yellow core
No
With smaller neutral conductor
No
Dimensional characteristics
Dimensional characteristics
Number of cores
1
Conductor cross-section
2.5 mm²
Phase Conductor Cross Section
2.5 mm²
Nominal insulation thickness
0.8 mm
Nominal outer diameter
3.9 mm
Approximate weight
30 kg/km
Neutral conductor section (when smaller)
- mm²
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
450/750 V
Max. DC resistance of the conductor at 20°C
7.41 Ohm/km
Maximum permissible nominal current
21 A
Voltage drop, single phase
18.0 V/A.km
Voltage drop, 3 conductors
15.0 V/A.km
Usage characteristics
Usage characteristics
Operating temperature, range
-5 ... 60 °C
Max. conductor temperature in service
70 °C
Short-circuit max. conductor temperature
160 °C
Resources
Resources
Current capacity table PVC insulation single core single phase
PVC insulation/two loaded conductors, copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in groundConductor cross-section | A1 Insulated conductors in conduit in a thermally insulated wall | B1 Insulated conductors in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | F Single-core flat cables, touching in free air | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Conductor cross-section 2.5 |
A1 Insulated conductors in conduit in a thermally insulated wall
19.5 |
B1 Insulated conductors in conduit on a wooden wall
15.0 |
C Single-core or multi-core cable on a wooden wall
24.0 |
D1 Single-core or Multi-core cable in ducts in the ground
18.5 |
D2 Single-core or Multi-core cables designed to be buried directly in the ground
27.0 |
F Single-core flat cables, touching in free air
21.0 |
mm² 29.0 |
Cu 22.0 |
Al 28.0 |
Cu 0.0 |
Al 0.0 |
Cu 0.0 |
Current capacity table PVC insulation single core three phase
PVC insulation/three loaded conductors, copper or aluminium – Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in groundConductor cross-section | A1 Insulated conductors in conduit in a thermally insulated wall | B1 Insulated conductors in conduit on a wooden wall | C Single-core or multi-core cable on a wooden wall | D1 Single-core or Multi-core cable in ducts in the ground | D2 Single-core or Multi-core cables designed to be buried directly in the ground | F Single-core flat cables, touching in free air | F Single-core trefoil cables, touching in free air | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
Conductor cross-section 2.5 |
A1 Insulated conductors in conduit in a thermally insulated wall
18.0 |
B1 Insulated conductors in conduit on a wooden wall
14.0 |
C Single-core or multi-core cable on a wooden wall
21.0 |
D1 Single-core or Multi-core cable in ducts in the ground
16.5 |
D2 Single-core or Multi-core cables designed to be buried directly in the ground
24.0 |
F Single-core flat cables, touching in free air
18.5 |
F Single-core trefoil cables, touching in free air
24.0 |
mm² 18.5 |
Cu 24.0 |
Al 0.0 |
Cu 0.0 |
Al 0.0 |
Cu 0.0 |
Al 0.0 |
Declaration of Performance
- Declaration of Performance n� : 1001106-GRLA
- Certification Date : 8/31/22
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : 0832
- Declared performance : Eca