- Company
- Markets
-
Products
- Products
- Building cables
- Outdoor/Industrial Non Armored Cables
- Outdoor/Industrial Armored Cables
- Earth Conductors
- Solar farms
- Safety Cables
- Power Distribution Aerial cables
- Power Transmission & Distribution Conductors OHL
- Power Distribution cables
-
MV Underground Armored cables
- Overview
- CU/XLPE/CTS/LSF/AWA/LSF 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV
- CU/XLPE/CTS/LSF/SWA/LSF 6.35/11 KV
- CU/XLPE/CTS/PVC/SWA/PVC 19/33KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33KV
- CU/XLPE/CTS/PVC/AWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33 KV RED STRIPE
-
MV Underground Unarmored cables
- Overview
- NA2XS(F)2Y RM 6/10 KV
- CU/XLPE/CWS/PE 6.35/11KV - BS 7870-4.10
- A2XS(F)2Y 12/20KV - IEC
- NA2XS(F)2Y RM 18/30 kV
- AL/XLPE/CWS/PVC 12/20KV - DEH
- NA2XS(F)2Y RM 12/20 kV
- CU/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- 2XSY 12/20 KV - IEC
- AL/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- AL/XLPE/PVC 12/20KV - triplex - Underground - DEH
- A2XSY 12/20KV - IEC
- CU/XLPE/CWS/PVC 12/20KV 3-CORE -IEC
- AL/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/CWS/WB/PE 19/33KV - BS 7870-4.10
- AL/XLPE/CWS/PE 19/33KV - BS 7870-4.10
- AL/XLPE/AWS/WB/PE 19/33KV
- AL/XLPE/CWS/PE/SC 19/33KV - BS 7870-4.10
- A2XSH 12/20KV - DEH
- AXCLIGHT TT 12kV
- AXCLIGHT TT E 36kV
- NA2XS(FL)2Y V RM 12/20 kV
- AXCLIGHT TT 24kV
- CU/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/AL-PE/PE 12/20KV 3.0 - IEC
- NA2XS(F)2Y RM 12/20 kV - triplex
- AL/XLPE/CWS/PE 6.35/11KV - BS 7870-4.20
- NA2XS(F)2Y V RM 12/20 kV
- AXLJ TT 36 kV
- CU/XLPE/AWS/LSF 6.35/11KV - IEC
- NA2XS2Y RM 6/10 KV - Triplex
- Newsroom
- Tools & Resources
- Newsletter
- Search
- Contact us
- Compare
- Sign in
BARE COPPER 6
BARE COPPER 6
BARE COPPER 6
Read more- Nexans ref. : 13001085
- Country ref. : 13001085
- EAN : 5204609010858
Description
Description
Standards
-
ProductIEC 60228
Application
Bare annealed copper conductor, soth drawn
Installation: in air or in ground
Design
The conductor is consisted of copper wires which are stranded together.
The construction and electrical characteristics of conductor is according of the international standard IEC 60228 for conductors class 2
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Copper
Conductor flexibility
Stranded class 2
Conductor shape
Circular
Dimensional characteristics
Dimensional characteristics
Number of cores
1
Conductor cross-section
6 mm²
Phase Conductor Cross Section
- mm²
Nominal outer diameter
3.3 mm
Approximate weight
50.1 kg/km
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
-
Max. DC resistance of the conductor at 20°C
3.08 Ohm/km
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania