A2XS(F)2Y 12/20KV - IEC

Products

A2XS(F)2Y 12/20kV 1X 50/16

Nexans ref. 13001822 - Country ref. 13001822

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Phase Conductor Cross Section: 50 mm²
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 29.0 mm

 

A2XS(F)2Y 12/20kV 1X 70/16

Nexans ref. 13006079 - Country ref. 13006079

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Phase Conductor Cross Section: 70 mm²
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 31.0 mm

 

A2XS(F)2Y 12/20kV 1X 95/16

Nexans ref. 13002038 - Country ref. 13002038

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Phase Conductor Cross Section: 95 mm²
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 33.0 mm

 

A2XS(F)2Y 12/20kV 1X120/16

Nexans ref. 13004356 - Country ref. 13004356

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Phase Conductor Cross Section: 120 mm²
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 34.0 mm

 

A2XS(F)2Y 12/20kV 1X150/25

Nexans ref. 13001074 - Country ref. 13001074

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Phase Conductor Cross Section: 150 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 36.0 mm

 

A2XS(F)2Y 12/20kV 1X185/25

Nexans ref. 13002039 - Country ref. 13002039

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Phase Conductor Cross Section: 185 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 38.0 mm

 

A2XS(F)2Y 12/20kV 1X240/25

Nexans ref. 13001800 - Country ref. 13001800

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Phase Conductor Cross Section: 240 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 40.0 mm

 

A2XS(F)2Y 12/20kV 1X300/25

Nexans ref. 13006021 - Country ref. 13006021

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²
  • Phase Conductor Cross Section: 300 mm²
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 43.0 mm

 

A2XS(F)2Y 12/20kV 1X400/35

Nexans ref. 13002946 - Country ref. 13002946

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²
  • Phase Conductor Cross Section: 400 mm²
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 2.3 mm
  • Nominal outer diameter: 47.0 mm

 

A2XS(F)2Y 12/20kV 1X500/35

Nexans ref. 13002742 - Country ref. 13002742

  • Packaging: Cut to length (m)
  • Conductor cross-section: 500 mm²
  • Phase Conductor Cross Section: 500 mm²
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 50.0 mm

 

A2XS(F)2Y 12/20kV 1X630/35

Nexans ref. 13003128 - Country ref. 13003128

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Phase Conductor Cross Section: 630 mm²
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 2.5 mm
  • Nominal outer diameter: 54.0 mm

 

Description

Description

Standards

  • International
    IEC 60502-2

Electric cable with stranded Aluminium conductor, conductor screen of semiconducting compound, XLPE insulation, insulation screen of semiconducting compound, copper wires metallic screen, water protection, PE outer sheath. Rated voltage 12/20 KV (Um=24KV)

 

Application

in grounds, outdoors, indoors and in cable ducts

 

Note:

on request the cables are available with copper helix tape above the copper wires metallic screen.

 

on request the cables are available with Low Smoke Zero Halogen (LSZH) outer sheath (A2XS(F)H)

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor flexibility
Stranded class 2
Halogen free
Yes
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE
Material of the external semi-conductor
Semi-conducting compound
Screen
Copper wire
Outer sheath
PE
Conductor shape
Circular

Dimensional characteristics

Dimensional characteristics

Number of cores
1
Nominal insulation thickness
5.5 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
12 / 20 (24) kV

Usage characteristics

Usage characteristics

Flame retardant
No
Longitudinal water tightness
Yes

Resources

Resources

Selling & delivery Information

Packing on wooden drums

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close