- Company
- Markets
-
Products
- Products
- Building cables
- Outdoor/Industrial Non Armored Cables
- Outdoor/Industrial Armored Cables
- Earth Conductors
- Solar farms
- Safety Cables
- Power Distribution Aerial cables
- Power Transmission & Distribution Conductors OHL
- Power Distribution cables
-
MV Underground Armored cables
- Overview
- CU/XLPE/CTS/LSF/AWA/LSF 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV
- CU/XLPE/CTS/LSF/SWA/LSF 6.35/11 KV
- CU/XLPE/CTS/PVC/SWA/PVC 19/33KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33KV
- CU/XLPE/CTS/PVC/AWA/PVC 12.7/22KV RED STRIPE
- CU/XLPE/CTS/PVC/SWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 6.35/11KV RED STRIPE
- CU/XLPE/CTS/PVC/AWA/PVC 19/33 KV RED STRIPE
-
MV Underground Unarmored cables
- Overview
- NA2XS(F)2Y RM 6/10 KV
- CU/XLPE/CWS/PE 6.35/11KV - BS 7870-4.10
- A2XS(F)2Y 12/20KV - IEC
- NA2XS(F)2Y RM 18/30 kV
- AL/XLPE/CWS/PVC 12/20KV - DEH
- NA2XS(F)2Y RM 12/20 kV
- CU/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- 2XSY 12/20 KV - IEC
- AL/XLPE/CWS/PE 6.35/11KV - TRIPLEX - BS 7870-4.10
- AL/XLPE/PVC 12/20KV - triplex - Underground - DEH
- A2XSY 12/20KV - IEC
- CU/XLPE/CWS/PVC 12/20KV 3-CORE -IEC
- AL/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/CWS/WB/PE 19/33KV - BS 7870-4.10
- AL/XLPE/CWS/PE 19/33KV - BS 7870-4.10
- AL/XLPE/AWS/WB/PE 19/33KV
- AL/XLPE/CWS/PE/SC 19/33KV - BS 7870-4.10
- A2XSH 12/20KV - DEH
- AXCLIGHT TT 12kV
- AXCLIGHT TT E 36kV
- NA2XS(FL)2Y V RM 12/20 kV
- AXCLIGHT TT 24kV
- CU/XLPE/AWS/PE 6.35/11KV - TRIPLEX - IEC
- AL/XLPE/AL-PE/PE 12/20KV 3.0 - IEC
- NA2XS(F)2Y RM 12/20 kV - triplex
- AL/XLPE/CWS/PE 6.35/11KV - BS 7870-4.20
- NA2XS(F)2Y V RM 12/20 kV
- AXLJ TT 36 kV
- CU/XLPE/AWS/LSF 6.35/11KV - IEC
- NA2XS2Y RM 6/10 KV - Triplex
- Telecom and Data
- Newsroom
- Tools & Resources
- Newsletter
- Search
- Contact us
- Compare
- Sign in
NA2XS2Y 10 3X1X185/25 C #D
NA2XS2Y 10 3X1X185/25 C #D
NA2XS2Y 10 3X1X185/25 C #D
Read more- Nexans ref. : 13006005
- Country ref. : 13006005
- EAN : 5204609067890
Description
Description
Standards
-
InternationalIEC 60502-2
-
NationalDIN VDE 0276 part 620
Construction
stranded aluminium conductor - conductor screen of semiconducting compound - insulation of cross-linked polyethylen (XLPE) - screen of semiconducting compound - semiconducting tape - screen of copper wires and copper tape - separation tape - PE sheath. Three single core cables are laid-up to form the triplex cable
Application
in ground, outdoors, in water, indoors and in cable ducts
This product is also part of our Windlink® offer dedicated to wind turbines.
Note: On request could be delivering three single core laid up cables on one drum
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Aluminum
Conductor shape
Circular
Conductor flexibility
Stranded class 2
Halogen free
Yes
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE
Material of the external semi-conductor
Semi-conducting compound
Material of bedding
Semiconducting tapes
Screen
Copper wire + copper tape
Protection
Separator tape
Longitudinally watertight
Outer sheath
PE
Sheath colour
Black
Lead free
Yes
Dimensional characteristics
Dimensional characteristics
Number of cores
1
Conductor cross-section
185 mm²
Phase Conductor Cross Section
185 mm²
Nominal insulation thickness
3.4 mm
Screen section
25 mm²
Nominal outer sheath thickness
2.5 mm
Nominal outer diameter
34.0 mm
Maximum outer diameter
37.0 mm
Minimum outer diameter
31.0 mm
Approximate weight
3820 kg/km
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
6 / 10 (12) kV
Perm. current rating buried 20°C - trefoil formation
357 A
Perm. current rating in air 30°C - trefoil formation
418 A
Max. DC resistance of the conductor at 20°C
0.164 Ohm/km
Usage characteristics
Usage characteristics
Packaging
Drum
Minimum installation temperature
-20 °C
Minimum operating temperature
-40 °C
Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Bending factor when laying
15 (xD)
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania