CEANDER 3X300AL+110CU SE #D #N #1

Description

Description

Standards

  • Product
    BS 7870-3.40; IEC 60502-1
  • Test
    IEC 60332-1-2

Construction

Aluminium sector shapped solid conductors, XLPE insulation, extruded inner covering, waveform conductor of copper wires, PVC outer sheath

 

Application

Outdoor applications. The cable is suitable for direct buried installation in ground and cable ducts. For single branch joints (T-joints) in local networks the concentric conductor can be connected uncut.

 

Core identification:

3-core: brown, black, grey

4-core: brown, black, grey, blue

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor shape
Sector-shaped
Conductor flexibility
Solid class 1
Insulation
XLPE
Concentric conductor
Bare copper wires
Outer sheath
PVC
Sheath colour
Black
Lead free
Yes
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
300 mm²
Phase Conductor Cross Section
300 mm²
Nominal insulation thickness
1.8 mm
Nominal outer sheath thickness
2.8 mm
Nominal outer diameter
56.0 mm
Approximate weight
4795 kg/km
Neutral conductor section (when smaller)
- mm²

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Max. DC resistance of the conductor at 20°C
0.1 Ohm/km
Permissible current rating when buried
461 A

Resources

Resources

Current capacity table XLPE insulation multicore single phase

XLPE or EPR insulation, two loaded conductors/copper or aluminium Conductor temperature: 90 °C, ambient temperature: 30 °C in air, 20 °C in ground
Conductor cross-section A2 Multi-core cable in conduit in a thermally insulated wall B2 Multi-core cable in conduit on a wooden wall C Single-core or multi-core cable on a wooden wall D1 Single-core or Multi-core cable in ducts in the ground D2 Single-core or Multi-core cables designed to be buried directly in the ground E Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
300.0 442.0 352.0 532.0 415.0 693.0 508.0 446.0 346.0 502.0 386.0 741.0 543.0

Current capacity table XLPE insulation multicore three phase

XLPE or EPR insulation, three loaded conductors/copper or aluminium – Conductor temperature: 90 °C, ambient temperature: 30 °C in air, 20 °C in ground
Conductor cross-section A2 Multi-core cable in conduit in a thermally insulated wall B2 Multi-core cable in conduit on a wooden wall C Single-core or multi-core cable on a wooden wall D1 Single-core or Multi-core cable in ducts in the ground D2 Single-core or Multi-core cables designed to be buried directly in the ground E Multi-core cable in free air
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
300.0 396.0 313.0 455.0 354.0 576.0 440.0 365.0 286.0 419.0 326.0 621.0 471.0

Declaration of Performance

  • Declaration of Performance n� : 1000703-GRLA
  • Certification Date : 4/18/18
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0832
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close